Power Generation Filtration Solutions
Filtration
Pumps
Flow Indicators
Gauges-Thermometers
Environmental
Liquid Handling
Meters
New Products
About Mid-States Sales
Contact Us
Line Card
Terms & Conditions
Home
|
Kaydon KL1 Dedicated Coalescing System with Automatic Water Drain and Totalizing Water Meter
Filtration Systems For FD-PA-ID Fan Reservoirs
KL1 (1 GPM) TURBO-TOC®
Get Quote
|
The Model KL1
Turbo-Toc® is a 1 GPM, Kidney Loop, Pressure Coalescence Turbine Oil Conditioner that continuously pumps oil from the main turbine reservoir, cleans and dries the turbine oil, and returns the turbine oil, under pressure, to the reservoir. It is designed for continuous, 24/7, operation and is engineered with continuous operation rated components. The KL1 is capable of maintaining "Reservoir Cleanliness" on a reservoir sized up to 120 gallons. This unit is ideal for Forced Draft (FD), Primary Air (PA), Induced Draft Fans (ID), for oils up to ISO 68 in Viscosity.
The Turbo-Toc® is a self-contained, skid mounted, micro-processor controlled, full status control panel, pressure coalescence system that features an automatic water drain and a totalizing water meter to help your power plant monitor water removal and/or predict critical maintenance.
|
FORMULA FOR
PROVIDING CLEAN/DRY TURBINE OIL
24 HOURS PER DAY
- Solid contamination and water removal in one very compact
design (21"L x 13"W x 30"H).
- 1 gpm continuous process rate for fast reservoir turnover
and generous reserve for emergencies.
- Suitable for reservoir capacities to 120 gallons.
- Extremely compact design mounts directly on or adjacent
to reservoir, less than 99 pounds dry.
- Removal of particulate smaller than bearing clearances
with absolute rated filter elements1.
- 80% single pass water removal.
- Low maintenance, operator not required.
- Very low operating cost.
- Simple installation.
|
|
MODEL KL1H (1 GPM)
Removes free and emulsified water and solid contamination
from small turbine and lube oil reservoirs, 1 gpm continuous
process rate for permanent off-line installation.
1 = 2.8 micron absolute rated filters test per ISO 4572.
2 = Influent 5000 ppm water, 200 ssu maximum turbine oil.
THE BENEFITS OF CLEAN/DRY LUBE OIL:
- Improve Reliability & Availability of Turbine
- Reduce Bearing & Seal Failures
- Fewer Forced Outages
- Extend Planned Outages
- Reduce Oil Disposal
APPLICATIONS:
- Industrial Steam Turbines
- Forced Draft Fan Turbines
- Induced Draft Fan Turbines
- Primary Air Fan Turbines
- Boiler Feed Pump Turbines
- Compressor Turbines
- High Speed Gearboxes
- Mechanical Drives
- Fluid Drives
- Any Small Turbine Oil Reservoir
OPERATING PARAMETERS:
- Permanent Installation
- 1 GPM Continuous Process Rate
- Reservoir Capacities to 300 Gallons
- Standard Oil, Mineral Based Turbine, ISO 68 Maximum
- Non-Standard Oils Require Manufacture's Approval
- Standard Voltage, 110 VAC
ORDER CODE
Model KL1-AA-WM-S
AA=automatic air release (releases any trapped air in system automatically)
WM=water meter (totalizes amount of water removed by KL1 TURBO-TOC®)
S=sample kit (this kit helps take samples of oil for analysis)
|
|